Cat.6  4-Pr  UTP

 

DESCRIPTION:


23 AWG /4 Pair RISER CATEGORY 6 DATA CABLE
COMPLIANCE:
(Meets or exceeds)


1. UL Listed Type CMR/MPR
2 .C(UL) listed CMG/MPG FT4
3 .NEMA WC-66 (Cat 6)ETL
4 .TIA/EIA 568B
5 .ICEAS-90-661

FEATURES:


1 .Provides enhanced performance over TIA/EIA Category 6,
    transmission requirements.
2 .Provides and additional 3dB NEXT margin over Category 6,
    requirements.
3 .Utilizes a small round filler design providing a smaller diameter
    and greater flexibility for easier handling.
4 .Lead free jacket.

Construction Parameters:

1 . DIAMETER*
2 . Conductors: Solid Copper 0.023
3 . Dielectric: Solid FRPE 0.042
4 . Assembly: Each pair has different lay length for cross-talk
     prevention and ripcord added.
5 . Jacket: PVC 0.230
     (* = Nominal value)

Electrical Properties:

  • DC Resistance Max.(ohms/100m @ 20°C): 9.38
  • DC Resistance Unbalance Max.(%): 5
  • Characteristic Impedance (ohms): 85-115
  • Pair-to-Ground Cap. Unbal. Max.(pF/100m): 330
  • ACR (@1-250 MHz): Positive
  • RL Max.(dB) @ 100MHz:17    250MHz: 14
  • Attenuation Max. @250 MHz (db/100m): 32
          The attenuation value is for information only. The maximum loss
           for any pair at room temp. is to be determined using the formula
          Att (f) < 1.967 [SQR (f) ] + 0.023 (f) + 0.050/SQR (f) Crosstalk
  • NEXT @250 MHz (db/100m): 38.3
  • PSNEXT @250 MHz (db/100m): 36.3
  • ELFEXT @250 MHz (db/100m): 19.8
  • PSELFEXT @250MHz (db/100m): 16.8
          The cross talk values are for information only. The min. crosstalk
           loss for any pair combination at room temp. is to be greater than
           the value determined using the formulas:
                      NEXT(fMhz)3NEXT(0.772)-15log10(fMhz/0.772),
                      PSNEXT(fMhz)3PSNEXT(0.772)-15log10(fMhz/0.772),
                      ELFEXT(fMhz)3ELFEXT(0.772)-20log10(fMhz/0.772),
                      PSELFEXT(fMhz)3PSELFEXT(0.772)-20log10(fMhz/0.772).

    Miscellaneous Information:
  • Pair Colors: W/BL with BL, W/OR with O, W/GR with GR, W/BR with  BR
  • Jacket Color: Standard colors are Blue and Gray
  • Flame rating: UL-1666 Vertical Shaft Flame Test CSA FT4 Vertical Flame Test
  • Applicable NEC Article: 800
  • Applicable TIA/EIA: WC-66 (Category 6)
  • Approx. Weight (lb/1000 ft): 26
  •    EZ-Panel
     
     1
     
     
     
     
    Girard Electronics Limited
    www.igirard.com | postmaster@igirard.com