DESCRIPTION:
23 AWG /4 Pair RISER
CATEGORY 6 DATA CABLE
COMPLIANCE:
(Meets or exceeds)
1. UL Listed Type CMR/MPR
2 .C(UL) listed CMG/MPG FT4
3 .NEMA WC-66 (Cat 6)ETL
4 .TIA/EIA 568B
5 .ICEAS-90-661
FEATURES:
1 .Provides enhanced performance over TIA/EIA Category 6,
transmission requirements.
2 .Provides and additional 3dB NEXT margin over Category 6,
requirements.
3 .Utilizes a small round filler design providing a smaller
diameter
and greater flexibility for easier handling.
4 .Lead free jacket.
Construction
Parameters:
1 . DIAMETER*
2 . Conductors: Solid Copper 0.023
3 . Dielectric: Solid FRPE 0.042
4 . Assembly: Each pair has different lay length for cross-talk
prevention and ripcord added.
5 . Jacket: PVC 0.230
(* = Nominal value)
Electrical
Properties:
DC Resistance Max.(ohms/100m @ 20°C):
9.38
DC Resistance Unbalance Max.(%): 5
Characteristic Impedance (ohms): 85-115
Pair-to-Ground Cap. Unbal. Max.(pF/100m): 330
ACR (@1-250 MHz): Positive
RL Max.(dB) @ 100MHz:17 250MHz: 14
Attenuation Max. @250 MHz (db/100m): 32
The attenuation value
is for information only. The maximum loss
for any pair at room
temp. is to be determined using the formula
Att (f) < 1.967 [SQR
(f) ] + 0.023 (f) + 0.050/SQR (f) Crosstalk
NEXT @250 MHz (db/100m): 38.3
PSNEXT @250 MHz (db/100m): 36.3
ELFEXT @250 MHz (db/100m): 19.8
PSELFEXT @250MHz (db/100m): 16.8
The cross talk values
are for information only. The min. crosstalk
loss for any pair combination
at room temp. is to be greater than
the value determined
using the formulas:
NEXT(fMhz)3NEXT(0.772)-15log10(fMhz/0.772),
PSNEXT(fMhz)3PSNEXT(0.772)-15log10(fMhz/0.772),
ELFEXT(fMhz)3ELFEXT(0.772)-20log10(fMhz/0.772),
PSELFEXT(fMhz)3PSELFEXT(0.772)-20log10(fMhz/0.772).
Miscellaneous
Information:
Pair Colors: W/BL with BL, W/OR with O, W/GR with GR, W/BR
with BR
Jacket Color: Standard colors are Blue and Gray
Flame rating: UL-1666 Vertical Shaft Flame Test CSA FT4
Vertical Flame Test
Applicable NEC Article: 800
Applicable TIA/EIA: WC-66 (Category 6)
Approx. Weight (lb/1000 ft): 26
|